M-6200 Digital Line Regulator Control®

Digital Regulator Control for General Electric, Siemens, Cooper and Howard Regulators.

Features

  • Conventional and Autodaptive® (Phase II) Control Methods
  • Adjustable Bandcenter
  • Adjustable Bandwidth
  • Line Drop Compensation, R, X and Z Compensation
  • Time Delay, Definite and Inverse
  • InterTap Time Delay
  • Selectable Outputs, Continuous or Pulsed
  • Reverse Power Operation for Single-Phase
  • Regulator applications
  • CT to VT Phasing Correction
  • Real-Time Metering of measured and calculated parameters
  • Demand Metering with selectable time interval
  • Drag Hands Operation
  • Adjustable Line Overcurrent Tapchange Inhibit
  • Voltage Limits
  • Tap Position Limits
  • Auto Runback
  • Three independent Voltage Reduction Steps
  • Sequential and Non-Sequential Operation
  • VT Ratio Correction
  • Tap Position Knowledge by "Keep Track" method
  • Operations Counter
  • Resettable Operations Counter
  • Harmonic Analysis (Phase II)
  • Tap Position Record
  • Auto/Off/Manual Switch Status
  • A or B Regulator Type Selection
  • User Programmable Alarm Contact
  • SCAMP™ (SCADA Controllable Auto/ Manual Pushbutton)
  • SCADA Cutout (Local/Remote) switch allows blocking of SCADA Commands
  • Control Voltage Input
  • Motor Power Input
  • Line Current Input
  • Raise Output
  • Lower Output
  • 20 Character by 2 Row LED backlit LCD Display
  • M-2029B TapTalk® Communications Software
  • M-2829 TapPlot™ Tap Analysis Software
  • USB Communications Port (12 Mbps)
  • VAr Bias
  • SD Card
  • SOE Sequence of Events
  • Data Logging
  • Oscillography (Phase II)
  • External Inhibit of Auto Tapchange
  • Front Panel LEDs for Out-of-Band Raise, Out-of-Band Lower, Reverse Power Flow Rev Pwr Detected, CPU OK, MANUAL, LOCAL, Voltage reduction V/RED in Effect, LDC in Effect Voltage Reduction 1 & 2 Inputs (Binary)
  • Neutral Position Detect (Binary)
  • Counter Input (Binary)
  • Seal-in/Switch Status Input (Binary)
  • Non-Sequential/SCADA Block Input (Binary)
  • COM1, RS-485 or Fiber Optics
  • Communication Protocols include DNP3.0, 2179 (Phase II) and MODBUS

Optional Features

  • Ethernet Port (Phase II) (10/100 Mpbs) is available through an RJ-45 jack. This port supports DNP over TCP/IP, MODBUS over
    TCP/IP, and IEC-61850 over TCP/IP
  • RS-232 Communications Port (Phase II)
  • Control Power Back-Up Input – input (+12 V dc) for backup of Fiber Optic loop-through communication
  • Local Wireless Bluetooth capability (Phase II)

Accessories

  • M-2026 AC-DC Control Power Backup Supply
  • M-2027 Control Power Backup Supply–AC Only


Sales and Service

For sales and service information contact your local representative or contact the factory:

E-mail: sales@beckwithelectric.com
Call (727) 544-2326 or Fax (727) 546-0121

Documentation & Software

En Español (Pulsar aquí)

  Instruction Manual
Download (1.88MB)
   
  Specifications
Download (400KB)
   
  Application Guide
Download (279KB)
   
  Application Note #29
Download (110KB)
   
  S-6200 TapTalk® Software
Download .ZIP Format (28.9MB)

 

Note: Documents are provided in Adobe Acrobat PDF format and require Acrobat 5.0 or higher to view.

Beckwith Electric Co., Inc. 6190-118th Avenue North Largo, Florida 33773-3724 U.S.A. 727-544-2326
© 2007 Beckwith Electric Co, Inc. All rights reserved. Home | Terms of Use | Privacy Policy | E-mail Webmaster