Integrated Generator Protection® Quick Reference Guide

Functions Available
Standard Functions
Standard Functions
Optional Functions
Optional Functions
 
Download a PDF of the
Quick Reference Guide
Print Version
 
Generator Protection
Transformer Protection
DG Interconnection Protection
Voltage Mitigation and Undervoltage/Underfrequency Load Shedding
Protective Function
Quick Reference Guide

ANSI
Function #
Description Generator Protection Intertie Protection Transformer Protection Intertie/
Generator Protection
M-3420 M-3425A M-3430 M-3520 M-3310 M-3311 M-3410A
21 Phase Distance (Mho characteristic)   Standard Functions* Standard Functions Optional Functions      
24 Volts/Hz Standard Functions Standard Functions Standard Functions   Optional Functions Optional Functions  
25 Sync-Check    Optional Functions     Standard Functions     Standard Functions
27 RMS Undervoltage, 3-Phase Standard Functions Standard Functions Standard Functions Standard Functions Optional Functions Optional Functions Standard Functions
27G RMS Undervoltage, Neutral         Standard Functions      
27TN Third-Harmonic Undervoltage, Neutral Circuit   Standard Functions * Standard Functions        
ANSI
Function #
Description Generator Protection Intertie Protection Transformer Protection Intertie/Generator Protection
M-3420 M-3425A M-3430 M-3520 M-3310 M-3311 M-3410A
32 Directional Power, 3-Phase Standard Functions Standard Functions Standard Functions Standard Functions     Standard Functions
40 Loss of Field Standard Functions Standard Functions Standard Functions       Standard Functions
46 Negative Sequence Overcurrent Standard Functions Standard Functions Standard Functions Standard Functions Standard Functions Standard Functions Standard Functions
47 Phase Rotation       Standard Functions     Standard Functions
49 Winding thermal protection   Standard Functions*       Standard Functions  
50 Instantaneous Overcurrent, 3-Phase Standard Functions Standard Functions   Standard Functions Standard Functions Standard Functions  
50/27 Inadvertent Energizing Standard Functions Standard Functions Standard Functions        
50BF Breaker Failure Standard Functions Standard Functions Standard Functions   Standard Functions Standard Functions  
ANSI
Function #
Description Generator Protection Intertie Protection Transformer Protection Intertie/
Generator Protection
M-3420 M-3425A M-3430 M-3520 M-3310 M-3311 M-3410
50DT Definite time overcurrent for split-phase differential   Standard Functions*          
50G or 50N Instantaneous Overcurrent, Neutral Standard Functions Standard Functions   Standard Functions Standard Functions Standard Functions  
50W1/W2/W3 Instantaneous Phase Overcurrent
(Dual elements per winding)
        Standard Functions Standard Functions  
51W1/W2/W3 Three winding inverse time phase overcurrent         Standard Functions Standard Functions  
51N Inverse Time Overcurrent, Neutral Standard Functions Standard Functions   Standard Functions     Standard Functions
51V Inverse Time Overcurrent, 3-Phase with Voltage Control or Voltage Restraint Standard Functions Standard Functions   Standard Functions     Standard Functions
ANSI
Function #
Description Generator Protection Intertie Protection Transformer Protection Intertie/
Generator Protection
M-3420 M-3425A M-3430 M-3520 M-3310 M-3311 M-3410A
51NW1/W2/W3 Inverse Time Residual Overcurrent         Standard Functions Standard Functions  
59 RMS Overvoltage, 3-Phase Standard Functions Standard Functions Standard Functions Standard Functions     Standard Functions
59D Third Harmonic Voltage Differential   Standard Functions*          
59G or 59N RMS Overvoltage, Neutral Circuit or Zero Sequence Standard Functions Standard Functions   Standard Functions Optional Functions Optional Functions  
59I Peak Overvoltage       Standard Functions     Standard Functions
59X Multipurpose overvoltage   Standard Functions          
60FL VT Fuse-Loss Detection Standard Functions Standard Functions Standard Functions Standard Functions     Standard Functions
64F Field Ground   Optional Functions          
64S 100% Stator Ground Fault by 20Hz Injection Optional Functions
67 Phase Directional Overcurrent       Standard Functions      
ANSI
Function #
Description Generator Protection Intertie Protection Transformer Protection Intertie/
Generator Protection
M-3420 M-3425A M-3430 M-3520 M-3310 M-3311 M-3410A
67N Residual Directional Overcurrent   Standard Functions    Standard Functions      
78 Out-of-step (Mho Characteristic) protection    Standard Functions*    Optional Functions      
79 Reconnect Time Delay       Standard Functions     Standard Functions
81 O/U Frequency Standard Functions Standard Functions Standard Functions Standard Functions Optional Functions Optional Functions Standard Functions
81A Underfrequency Accumulation   Standard Functions*          
81R Rate of Change of Frequency   Standard Functions*   Optional Functions      
87 Phase Differential Current Standard Functions Standard Functions Standard Functions        
87GD Ground (zero sequence) Differential Standard Functions Standard Functions     Standard Functions Standard Functions  
ANSI
Function #
Description Generator Protection Intertie Protection Transformer Protection Intertie/
Generator Protection
M-3420 M-3425A M-3430 M-3520 M-3310 M-3311 M-3410A
87H Phase Differential High Set Overcurrent           Standard Functions Standard Functions  
87T Phase Differential (Harmonic Restrained)          Standard Functions Standard Functions  
EXT External Standard Functions Standard Functions Standard Functions   Standard Functions Standard Functions  

* Functions available in Comprehensive Protection Package only.
† Note: On the M-3425A when 50 DT is selected, 50BF, 87, and 87GD functions are not available.