Protection & Control Seminar
Protection & Control Seminar
July 30 - August 2, 2018
Clearwater Beach, FL

Distribution Protection & Control Track

Wednesday, August 1, 2018

Breakfast

7:00-8:00 AM


Transformer Protection
Instructor: Wayne Hartmann

Based on IEEE C37.91. Transformers are subject to internal faults, the effects of external faults and abnormal operating conditions impressed by the power system events the transformer no control over but must cope with. False (nuisance) trips are costly as the transformer and load are disconnected. Inability to trip due to lack of sensitivity, lack of certain protections or deficiencies in protection application may cause severe damage to transformers, negatively impact power quality and upset stability. Achieving the ideal balance of secure and dependable protection involves use of an array of elements that protect the transformer from prolonged internal faults, excessive through faults, when challenged by power system faults and anomalies.

  • Why transformers fail
    • The cost of failures
  • IEEE C37.91, Guide for Power Transformer Protection
  • Common transformer, bus and breaker connections
  • Explore non-electrical protections
    • Buccholtz (63)
    • Sudden pressure (63)
      • Sudden pressure relay supervision schemes
    • Thermal (49)
  • Explore electrical protections
    • GIC events
    • Overcurrent based (50, 51, 50N, 51N, 46)
    • Through fault protection (TFM)
    • Overexcitation (24)
      • Generating plant causes
      • T&D system causes
    • Differential: high set (87HS), restrained (87T) and ground (87GD)
    • CT performance issues (saturation, remenance, X/R ratio)
      • Transformer protection challenges (phase shift, ratio difference, inrush, grounding)
      • Percentage differential characteristics
      • Restraints for inrush and Overexcitation
        • Adaptive restraint for security
  • Realization of settings
  • Tools to view relay operation
    • Commission examples

8:00-10:00 AM


Break

10:00-10:15 AM


Transformer Protection (Continued)

10:15 AM-Noon


Lunch

Noon-1:00 PM


Transformer Protection (Continued)

1:00-2:45 PM


Break

2:45-3:00 PM


Option 1:
Transformer Protection Calculations & Settings - Differential Elements

Instructor: Dr. Murty Yalla
Building on the base knowledge covered in Transformer Protection Fundamentals, calculations for protective elements are developed. Depending on the element, these calculations use nameplate data, system data or a combination of the two. Margin considerations are explored and impacts on element reliability are discussed, as well as element interdependencies with protection and control in the transformer zone, whether in generation, transmission or distribution.

3:00-5:30 PM

Option 2:
Transformer Protection Hands-on Testing Lab Breakout Session
(Register early as seats will be limited for Breakout Session!)

3:00-5:30 PM


Wednesday Evening Activities

  • Wednesday Evening Reception
    • The Brown Boxer Pub & Grille
      483 Mandalay Ave, Clearwater Beach, FL 33767 (Across the street from the Sandpearl Resort)
    • 6:00-8:00 PM
    • Join Beckwith Electric and your fellow conference attendees for a reception with food and cocktails at the Brown Boxer from 6:00-8:00 PM. The Brown Boxer is located right across the street from the Sandpearl Resort.