M-2980A

M-2980A Weatherproof Capacitor Control Cabinet


M-2980A
Molded Lexan® Enclosure Shown With
Optional M-6280A Capacitor Bank Control
  • NEMA® 4 rated enclosures available in the following construction materials:
    – Nonmetallic Polycarbonate
    – Molded Lexan®
    – Cold Rolled Steel
    – Stainless Steel
  • UV resistant
  • Locking clasps accept 3/8” hasp locks
  • Flexible configurations allow adaptation to a wide range of applications

Application

Each M-2980A enclosure can be configured with the optional support equipment to match the existing control application and environment or supplied completely empty.

Construction

Polycarbonate

  • Bodies and doors fabricated from nonmetallic polycarbonate
  • EPDM gasket (ethylene propylene diene Monomer- M-class)
  • External adjustable mounting bracket
  • Non-metalic door hinges
  • Enclosure door accommodates optional power supplies and communications devices
  • External Grounding stud provided

Molded Lexan®

  • Bodies and doors fabricated from molded Lexan
  • EPDM gasket (ethylene propylene diene Monomer- M-class)
  • External adjustable mounting bracket
  • Non-metalic door hinges with stainless steel hinge pin
  • Enclosure door accommodates optional power supplies and communications devices
  • External Grounding stud provided

Cold Rolled Steel/Stainless Steel (304)B7B346

  • Bodies and doors fabricated from 14/16 gauge steel
  • Continuously welded seams ground smooth
  • Closed cell neoprene gasket
  • External adjustable mounting bracket
  • Stainless steel door hinge
  • Enclosure accommodates optional power supplies and communications devices
  • External Grounding stud provided

Cabinet to Capacitor Bank Interface Type

  • Meter Socket Mount
    • Integrated 4, 5 or 6 Blade (4 Blade Standard) Meter Socket Plug
    • Standard Meter Socket Plug wiring is available in factory 4, 5 and 6 Blade configuration (4S, 5S and 6S)
    • Optional custom factory Meter Socket Plug wiring configurations available

  • Direct Pole-Mount with cabled Meter Socket Plug
    • 4, 5, or 6 Blade (4 Blade standard) Meter Socket Plug with standard five foot control cable
    • Standard Meter Socket Plug wiring is available in factory 4, 5 and 6 Blade configuration
    • Optional cable lengths available in five foot increments up to 50 feet
    • Optional Factory Meter Socket Plug Custom Wiring Configurations available

  • Direct Pole-Mount with Cannon Connector, Integrated
    • 5-Pin Cannon Connector (Figure 2), Cannon Bulkhead Shell 18-21
    • 7-Pin Cannon Connector (Figure 3), Cannon Bulkhead Shell 20-15
    • Optional 5 and 7-Pin wiring configurations available

  • Direct Pole-Mount with Cannon Connector, Cabled
    • 5-Pin Cannon Connector Shell 18-21
    • 7-Pin Cannon Connector Shell 20-15
    • Optional 5 and 7-Pin wiring configurations available
    • Optional cable lengths available in five foot increments up to 50 feet

  • Direct Pole-Mount with cable only, no connector

Optional Equipment/Accessories

  • M-6280A Digital Capacitor Bank Control

  • Pole mount bracket

  • Load Current Sensor Options Include:
    • 15 KV Fisher Pierce Line Post Sensor - Includes 35 ft. cable with 3-Pin Cannon connector and Cabinet Side Connection.
    • 15 KV Lindsey Line Post Sensor
    • 30 Foot Cable for Lindsey Line Post Sensor

  • Neutral Current Sensor Options Include:
    • 50:0.2 CT Neutral Current Sensor terminated with 3-Pin Cannon connector (Figure 4) using
      customer specified (10, 20, 35, or 45 foot) length of shielded twisted pair cable. Includes Cabinet
      Side Connections installed in hole location N.
    • 50:0.2 CT Neutral Current Sensor with customer specified (10, 20, 35, or 45 foot) length of shielded twisted pair cable.
    • Cannon Connector, cabinet side 3-Pin

  • Antenna Cable & Bulkhead Connector (For Installation with Antennas Mounting Direct to Cabinet) options
    include:
    • TNC male to N female weatherproof bulkhead and antenna cable for lid mount.
    • SMA male to N female weatherproof bulkhead and antenna cable for lid mount.
    • SMA male to N female weatherproof bulkhead and antenna cable for cabinet mount.
    • Double-D Hole for “N” connections in location 1, 2, 3 or 4 of cabinet to accommodate antenna exit.

  • Lightning Protection (For installations with external antennas) options include:
    • DSXL PolyPhaser Lightning Arrestor 700MHz - 2.7GHz N Female protected side, N Female Bulkhead antenna side.
    • AL-LSXM Polyphaser Lightning Arrestor 2 GHz to 6 GHz N Female protected side, N Female Bulkhead antenna side.
    • SMA male to N male antenna cable to connect lightning protection to a radio for cabinet mount.
    • TNC male to N male antenna cable to connect lightning protection to a radio for cabinet mount.

  • Antennas:
    • Laird FG9023, 902 MHz to 928 MHz, 3 dBi gain, fiberglass Omni-Directional antenna, N Female connector.
    • FM2, antenna Pole Mount Bracket for Laird fiberglass antennas.
    • Laird TRAB9023NP, 902 MHz to 928 MHz, 3 dBi gain, Omni-Directional Phantom antenna, N
    • Female bulkhead connector.
    • SMA male to N male antenna cable to connect antennas with an integrated bulkhead to a radio for cabinet mount.
    • TNC male to N male antenna cable to connect antennas with an integrated bulkhead to a radio for cabinet mount.

  • Radio Options Include:
    • 2 Way VHF (154 MHz) radio
      • Radius

    • 2 Way (130 MHz - 3.7 GHz) radio modems:
      • SilverSpring Networks SSN ebridge and sbridge
      • MDS INET 900 AP
      • MDS INET II
      • MDS SD9
      • MDS X710
      • MDS SD4
      • MDS 9810
      • MDS TransNET
      • MDS Mercury 3650 and 900
      • MDS entraNET 900 and 2400
      • CellNet Series III

    • Digital Cellular Modems:
      • Sixnet BT series Mobility Pro/industrial Pro Gateways
      • Multitech Multimodem series routers and modems
      • AirLink Raven II, X, XE

    • Radio ready options include:
      • Universal Radio Bracket
      • Universal Radio Bracket with 12 V dc or 24 V dc power Supply
      • Universal Radio Bracket with customer supplied power supply installed

    • Radio, Factory Installation:
      • Radio mounted and installed to M-2980A
      • Customer supplied radio mounted and installed to M-2980A

    • RS-232 Radio Comm Cable - 30” length. Connects M-6280A Control to radio’s DB9 Port
    • Ethernet Radio Comm Cable - 24” length. Connects M-6280A Control to radio’s RJ45 Port
    • Universal Power Cable provides fused 120 VAC to power a radio power supply (Included on all radio brackets)
    • DB9 to DB25 - RS-232 Cable Converter
    • Intrusion Detection Microswitch assembly
    • 1/2” HEYCO Liquid Tight Cordgrip to secure cable coming into cabinet via hole location “T” or “B”.
    • Universal Radio/Modem Bracket (For field mounting in the door of the M-6280A)
    • 12 V dc Power Supply for radio
    • 24 V dc Power Supply for Radio
    • 25 foot N male to N male LMR-400 antenna extension cable

Physical

  • Polycarbonate Cabinet
    • Size: 15.69” high x 13.19” wide x 7.27” deep (39.9 cm x 33.6 cm x 18.5 cm)
    • Approximate Weight: 9 lbs (4.1 kg)
    • Approximate Shipping Weight: 13 lbs, 5 oz (6.05 kg)
    • Approximate Weight with M‑6280A Digital Capacitor Bank Control: 15 lbs, 5 oz (7.02 kg)
    • Approximate Shipping Weight with M‑6280A: 23 lbs, 10 oz (10.61 kg)

  • Molded Lexan® Cabinet
    • Size: 18.38” high x 12.43” wide x 7.81” deep (46.7 cm x 31.6 cm x 19.84 cm)
    • Approximate Weight: 12 lbs (5.44 kg)
    • Approximate Shipping Weight: 10 lbs, 8 oz (4.76 kg)
    • Approximate Weight with M‑6280A Digital Capacitor Bank Control: 18 lbs (8.17 kg)
    • Approximate Shipping Weight with M‑6280A: 21 lbs, 8 oz (9.75 kg)

  • Cold Rolled Steel/Stainless Steel (304)B7B346
    • Size: 21.3” high x 11.12” wide x 7.71” deep (54.1 cm x 28.25 cm x 19.58 cm)
    • Approximate Weight: 15 lbs, 8 oz (7.03 kg)
    • Approximate Shipping Weight: 23 lbs (10.4 kg)
    • Approximate Weight with M‑6280A Digital Capacitor Bank Control: 22 lbs, 8 oz (10.21 kg)
    • Approximate Shipping Weight with M‑6280A: 35 lbs (15.88 kg)

Warranty

The M‑2980A Weatherproof Capacitor Control Cabinet is covered by a five year warranty from date of shipment. Third party mounted options will carry their respective manufacturer’s warranty, passed along through Beckwith Electric.

Specification subject to change without notice.


Sales and Service