Quick Reference Guide > M-2001 Control Features

Beckwith Electric’s M-2001 Tapchanger Control line introduces a unique concept in replacements by using a single tapchanger control—the M-2001—with interchangeable adapter panels. These panels are sized to correspond to the original manufacturer’s controls and use the same mountings and wiring harnesses that match the existing connections, for easy replacements.

The M-2001 Tapchanger Control is micro-controller-based using digital signal processing technology and waveform sampling to accurately and reliably measure system parameters. The M-2001 mounts easily to any of the adapter panels using four screws and a quick disconnect plug.

The result is a universally-applied control attached to identically-designed replacement panels.

Adapter
Panel
Features of
Adapter Panels
Features of M-2001 Tapchanger Control
M-2067
M-2174A*
M-2286A*
M-2339A*
M-2357*

Replacement panels indicated by an * include the M-2067 Adapter Panel and must be used with the M-2001 Digital Tapchanger Control (see description for standard features included with the
M-2001).

Standard features of the M-2067A include:
•voltage-sensing fuse that can be changed from the front panel
•provision for circulating current paralleling using the M-0115A Parallel Balancing Module

True rms voltage measurement techniques meet ANSI/IEEE ± 0.7% accuracy requirement from -40 to +80C responding
to the fundamental frequency component of voltage only.

Standard features of the M-2001 Tapchanger Control include:
•definite or inverse time characteristic
•±R / ±X line drop compensator
•LDC-Z line drop compensation
•band-edge LED indicators
•in-service testing using the bias voltage feature
•three-step voltage reduction
•reverse power detection and automatic regulation
•display of system parameters
•demand metering
•circulating current paralleling method
DVAr™ paralleling methods (optional)
•self-test alarm and user-programmable alarm
•RS-232, RS-485, and fiber optic serial communication ports
•date/time stamping of maximum/minimum conditions
•line overcurrent tapchange inhibit
•voltage limiting and automatic runback
•remote inhibit of auto operation
•sequential, non-sequential or pulsed operation
•tap position knowledge
•long-term data logging
•several on-board protocols
•KWHr and KVArHr metering
•TapTalkŪ Communications Software including harmonic analysis and Palm OSŪ software
•tap and voltage limits
•frequency of tap position operation record

   
M-2131A
M-2148A
M-2264
M-2270A
M-2271A
M-2278A
M-2279C
M-2280A
M-2293A
M-2323
M-2324B
M-2326A
M-2345A
M-2347A
M-2354B
M-2355A
M-2356B
M-2379A

Adapter panels must be used with the
M-2001 Tapchanger Control (see description for standard features included with the M-2001).

Standard features include:
•Auto/Off/Manual switch
•Raise/Off/Lower switch
•Voltage Source switch
•front-panel fuses for motor power, test terminal and voltage testing
•in-place testing capabilities with front-panel binding posts
•drag hands reset pushbbutton
•neutral light

Provision for the inclusion of the M-0329 LTC Backup Control is available as an option on the M-2279C and M-2379A only.

Regulator Controls
Transformer Controls
M-2001B Features
Auxiliary Controls
Instructions
Quick Reference Guide Home

 

 

Download a PDF of the
Quick Reference Guide

Beckwith Electric Co., Inc. 6190-118th Avenue North Largo, Florida 33773-3724 U.S.A. 727-544-2326
© 2006 Beckwith Electric Co, Inc. All rights reserved. Home | Terms of Use | Privacy Policy | E-mail Webmaster