IEEE PES Transmission and Distribution Conference & Exposition

Beckwith Electric Co. invites you to attend the 2006 IEEE PES Transmission and Distribution Conference and Exposition, May 21-26, 2006. While we had all hoped that the event could be held in New Orleans, it has become increasingly clear that the rebuilding task in front of our friends in New Orleans is far from over. As a result, the IEEE PES Governing Board has decided to move the conference to the city of Dallas.

The Conference and Exposition provides attendees with a comprehensive learning experience with presentations at the Opening Session focusing on the major issues of the day. The Opening Session is complemented by four Super Sessions that examine the Valuation of Transmission Assets, The Future of Wind Power, Cyber Security and Reactive Power.

Beckwith Electric invites you to attend the Transmission and Distribution Conference for one day at the discounted rate of $35.00.

How to register:

  • ADVANCE: Go to www.ieeet-d.org to register online.
    (Note: You will need to enter the validation code "2022" to register and receive the discounted rate.)
  • ONSITE: Present the completed form to a Registration Agent at the show. Click here to download a discount form.

Beckwith Electric looks forward to seeing you at the show!



Featured Products


New M-2001C Models - More options at lower prices!

Beckwith Electric now offers four M-2001C models to better match user applications while offering price concessions including the Comprehensive, Base-T, Base-RS, and Base-R.

  • M-2001C Comprehensive
    The Comprehensive can be applied to any LTC transformer, substation regulator, or line regulator and provides every feature, function and option available for a SCADA communicating device.
  • M-2001C Base-T
    The Base-T is intended primarily for those LTC transformer applications not requiring SCADA communications. It includes all necessary communication and inputs for transformer paralleling.
  • M-2001C Base-RS
    The Base-RS is our latest model and targets regulator applications requiring SCADA communications through RS485 but comes with a new lower price.
  • M-2001C Base-R
    The M-2001C Base-R is the most cost-reduced model targeting line regulator applications that do not require SCADA communications.

M-2948 & M-2949 Tap Position Sensors
  • Directly interfaces with the M-2025C Current Loop Interface which provides the tap position to the M-2001C Tapchanger Control
  • M-2948 — measures a 0° to 288° rotation, for use with a Qualitrol Position Indicator, Model 081-002-01 or equivalent
  • M-2949 — measures a 0° to 320° rotation, for use with a Qualitrol Position Indicator, Model 082-020-01, 082-001-01, or equivalent

Maintain Viability & Integrity of Critical Plant Process!

Digital Motor Bus Transfer System M-4272

  • Provides Automatic and Manual transfer of motor bus systems in power plants and industrial processing plants to ensure process continuity
  • Automatically selects Fast, Delayed In-Phase, Residual Voltage, and Fixed Time motor bus transfers, based on varying system conditions
  • Applicable for one-way and bi-directional Manual and Automatic transfers
  • Can accommodate two and three-breaker configurations
  • Multiple setpoint profiles for various application requirements
  • Integrated control, supervisory functions, sequence of events, and oscillograph recording in one device
  • Extensive commissioning tools, including ringdown analysis


Check out the new M-3425A with Expanded I/O
(15 additional Output Contacts and
8 additional Control/Status Inputs)

M-3425A Generator Protection System

Visit our booth to learn about the Integrated Protection System® for Generators of All Sizes. The M-3425A provides protection, control, monitoring and user interface functions for generator protection.

The Integrated Protection System M-3425A provides protection, control, monitoring and user interface functions for generator protection. Stored targets and oscillography can be IRIG-B synchronized. Dual RS-232 ports and an RS-485 port provide user-interface communication capabilities. The M-3820D IPScom® Communications Software is included for direct serial or remote communication access. Waveform data can be downloaded using the M-3801D IPSplot® PLUS Oscillograph Analysis Software which allows for plotting and printing of the downloaded oscillographic data.

  • Exceeds IEEE C37.102 and Standard 242 requirements for generator
    protection
  • Protects generators of any prime mover, grounding and connection type
  • Provides all major protective functions for generator protection including
    Out-of-Step (78), Split-Phase Differential (50DT), Under Frequency Time
    Accumulation (81A), Inadvertent Energizing (50/27) and Turn-to-Turn Fault
    (59X)
  • Expanded IPScom® Communications Software provides simple and logical
    setting and programming, including logic schemes
  • Simple application with Base and Comprehensive protection packages
  • Load encroachment blinders and power swing blocking for system backup
    protection (21) to enhance security during system abnormal conditions
  • Options: Ethernet Connection, Field Ground/Brush Lift-Off Protection (64F/B), Sync Check (25), 100% Stator Ground Fault Protection by low frequency injection (64S) and Expanded I/O (15 additional Output Contacts and 8 additional Control/Status Inputs)



SEE THE NEW M-3311A!


Protect Your Most Valuable Assets! Protection of Transformers and Other Important Power System Application.

  • Now with 4 Winding Protection for Transformers of All Sizes with Selectable Winding Configuration
  • Restricted Earth Fault Protection
  • 2nd & 4th Harmonic Restraint for Inrush
  • 5th Harmonic Adaptive Pickup Ride-through
  • V/Hz Load Shedding
  • Internal Compensation for Transformer Winding Configuration
  • Expanded Sequence of Events Logging
  • Unit Overall Differential - Enhance Security and Operational Use
  • Expanded I/O with 8 additional inputs & 16 outputs
  • IPSlogic - Customized Logic Schemes for External Functions
  • Ethernet Connection - Modbus & DNP3.0 over TCP/IP
  • Live On-Board Commissioning Tools

 


Communicate with Remote Field Assets!



M-2980
Be sure to visit booth #2022 to see the controls that "speak" the SCADA language of distribution system "field asset" automation. Beckwith Electric's new CellNet/Atos (UtiliNet) enabled, SCADA-ready capacitor control and line regulator control not only enable utilities to communicate with end devices in the field, it provides distributed control throughout the network. This enables you to make distribution planning decisions based on data collected today or last year. All this information is available directly from a control center and without wires.

M-5293

2006 IEEE PES
Transmission and Distribution
Conference and Exposition

May 21-26, 2006

Booth #2022


Dallas Convention Center
650 S. Griffin St.
Dallas, TX 75202

Map & Directions to Dallas Convention Center
Click here to register online

Exhibit Hall Hours
Mon., May 22 - 10 AM - 5:00 PM
Tue., May 23 - 10 AM - 6:00 PM
Wed., May 24 - 10 AM - 3:00 PM


Featured Events

Poster Session
Monday, May 22
1:00-3:00 PM

"Distributed Generator Interconnect Protection Practices"
By: Chuck Mozina



Poster Session
Monday, May 22
1:00-3:00 PM

"Advanced Tapchanger Control Features - and When to Use Them!
(Part One)"
By: Tom Jauch



Poster Session
Tuesday, May 23
10:00-12:00 PM

"Advances in Multifunction Digital
Transformer Relays"
By: Chuck Mozina



Poster Session
Wednesday, May 24
10:00-12:00 PM

"Factors in Choosing Transformer Paralleling Methods"
By: Tom Jauch



Info Session
Room D223
D Meeting Rooms
at Convention Center
Tuesday, May, 23
2:30-3:30 PM

"Transformer Paralleling"
By: Tom Jauch


Beckwith Electric Co., Inc. 6190-118th Avenue North Largo, Florida 33773-3724 U.S.A. 727-544-2326
© 2006 Beckwith Electric Co, Inc. All rights reserved. Home | Terms of Use | Privacy Policy | E-mail Webmaster